During CAM preparation of a 4-layer HDI order classified as 1-order, our team prepared a panel drawing and requested confirmation of its layout and separation method. The board measures 37 mm by 26.6 mm, uses Kingboard KB-6160 FR-4 with TG130, is specified at 0.8 mm finished thickness with 0.5 oz and 1 oz copper, carries green solder mask and white silkscreen, and includes blind and buried vias. The hole size is listed as 0.3 mm, via cover with solder mask is indicated, the surface finish is immersion gold at 1U", and mechanical forming is specified. Delivery quantity is 20 pieces in 5 sets. These parameters describe a small 1-order HDI construction in which the working panel format directly affects handling, plating uniformity, and final separation.
The main engineering communication submitted a 2×2 panel drawing that incorporates 4 mm process edges on all four sides, 2 mm routing clearance, and a forming method of bridges plus stamp holes, and asked for confirmation. A follow-up note recorded that the customer had replied the panel was acceptable yet final delivery would be as single pieces, which could not be controlled, and therefore requested reconfirmation of the same panel drawing.
4-Layer HDI Panelization: 2×2 Array with 4 mm Process Edges
The panel drawing shows a 2×2 array of the 37 mm by 26.6 mm circuits surrounded by 4 mm process edges on every side. We submitted the drawing for confirmation. On a small HDI board ( #HDI-20260718-0002 ) the process edge provides space for tooling holes, plating thieves, and handling margins that improve current distribution during immersion-gold plating and protect the functional area during mechanical forming. The 4 mm width matches the process-edge call-out already present on the order form and supplies sufficient border for the 0.8 mm thick construction without excessive material waste.
Because the order indicates a panel schematic and a 2×2 arrangement, the drawing refines rather than invents the array. The edges also accommodate the routing clearance described below and keep the blind-via and half-hole-free outline clear of panel tooling. Confirmation of the 4 mm borders locks the working panel outline before drill, plating, and routing programs are generated.
HDI Panel Routing Clearance: 2 mm Separation Spacing
The same drawing specifies 2 mm routing clearance at the separation locations. Routing removes a narrow strip of material so that the individual circuits can be broken apart after the bridges and stamp holes have served their purpose. A 2 mm clearance provides tool access and reduces the risk of the router bit striking adjacent copper or the 0.3 mm holes on this compact layout.
The order lists routing separation and a 2.00×2.00 mm routing spacing, so the 2 mm value is consistent with the form. On a 0.8 mm board with 1-order blind vias the clearance must also avoid undercutting the laser-drilled features or the resin-free via covers. Confirmation of the clearance dimension ensures the routing path remains clear of functional circuitry while still allowing clean depanelization of the 2×2 array.
HDI Depanelization: Bridge and Stamp-Hole Separation Method
The proposed forming method combines bridges with stamp holes. Bridges are narrow tabs of board material that hold the circuits in the panel through plating and solder-mask processing; stamp holes are small drilled or punched perforations that weaken the bridges so they can be snapped or routed apart with minimal burr. We included both features in the panel drawing and requested confirmation.
For a 20-piece order the 2×2 panel yields five panels, a convenient multiple that supports handling of the small 37 mm by 26.6 mm circuits. The bridge-and-stamp combination is a standard mechanical-forming approach when full routing of every edge is unnecessary. The stamp holes must be sized and placed so they do not intersect the 0.3 mm functional holes or the green solder-mask openings. Confirmation of the method locks the break-away geometry before the mechanical programs are released.
HDI Panel Confirmation: Resolving Single-Piece Delivery Requirements
After the initial panel submission the customer replied that the panel was acceptable yet final delivery would be as single pieces, which could not be controlled. We therefore resubmitted the identical 2×2 drawing—with its 4 mm process edges, 2 mm routing clearance, and bridge-plus-stamp-hole separation—and asked for reconfirmation. The follow-up highlights a practical distinction: the factory can process and plate the boards in panel form, but if the customer requires guaranteed single-piece shipment the panel must still be fully separated before packing, or the delivery format must be explicitly accepted as panels.


2×2 panel drawing
Because the order quantity is 20 pieces in 5 sets and the form already shows a panel schematic, the reconfirmation clarifies whether the 2×2 array is only a manufacturing convenience or whether the customer expects to receive intact panels. The inability to “control” single-piece delivery typically means that once the bridges are broken the individual boards can no longer be tracked or handled as a matched set; reconfirming the drawing resolves whether that outcome is acceptable. The same drawing continues to define the process edges and separation features regardless of the final packing format.
CAM Engineering Review: HDI Panel Design and Manufacturing Alignment
The panel drawing is the sole focus of the main engineering query for this 4-layer 1-order HDI board. The 2×2 array with 4 mm process edges supplies the handling and plating margin required for the 0.8 mm construction and its blind vias. The 2 mm routing clearance and the bridge-plus-stamp-hole method define how the circuits will be separated after processing. The reconfirmation step addresses the customer’s statement that single-piece delivery cannot be controlled, ensuring that both parties agree on the manufacturing format even if the boards ultimately ship individually.
No other stackup, via-diameter, or mask changes appear in the main query; the order form already lists no stackup requirement and via cover with solder mask. Once the panel drawing is reconfirmed, the working array, process-edge width, routing paths, and break-away features can be frozen. The boards can then proceed through imaging, lamination, laser or mechanical drilling of the 1-order vias, outer-layer processing, and mechanical separation according to the agreed bridges and stamp holes. The case shows how CAM review of a small HDI order can center on a single, repeated confirmation of panel geometry and separation method when delivery format and manufacturing format must be explicitly aligned.